Hello,
I am using the simple OTA example to update my app.
I can successfully relfash OTA0 from the Factory app and boot into OTA0.
However, if I go to back to Factory to reflash again, it still uses OTA0. Shouldn't it point to OTA1 for the next update?
Everytime I check esp_ota_get_next_update_partition, it does not seem to point to OTA1 ever....
I am on a 16mb flash size, using the below partition table.
nvs data nvs 0x4000
otadata data ota 0x2000
phy_init data phy 0x1000
factory app factory 2M
ota_0 app ota_0 4M
ota_1 app ota_1 4M
OTA1 Never used with Simple OTA
-
- Posts: 9759
- Joined: Thu Nov 26, 2015 4:08 am
Re: OTA1 Never used with Simple OTA
I'm not too familiar with OTA, but probably not. The OTA0/OTA1 scheme mostly is there because you can't flash over a running firmware. If you use the factory flash to do OTA, there's no such limitation.
Re: OTA1 Never used with Simple OTA
https://docs.espressif.com/projects/esp ... artition_tesp_ota_get_next_update_partition
Return the next OTA app partition which should be written with a new firmware.
Call this function to find an OTA app partition which can be passed to esp_ota_begin().
Finds next partition round-robin, starting from the current running partition.
So, if you start each time from factory then next boot partition is always ota0.
Who is online
Users browsing this forum: GOT666 and 117 guests