the ESP32 version of OpenOCD (0.9.0 ) no longer finds my ESP32 DevKit or Olimex Tiny-H, was fine before recent Win10 upgrade.
With max debug all goes well until it tries to talk to the driver
bin\openocd.exe -d3 -c "gdb_port 51558" -c "telnet_port 51559" -f olimex-arm-usb-tiny-h.cfg -c "adapter_khz 3000" -f esp32.cfg -
.... Lots of debug
Debug: 279 2225 command.c:364 register_command_handler(): registering 'ocd_set_core'...
Debug: 280 2235 ftdi.c:657 ftdi_initialize(): ftdi interface using shortest path jtag state transitions
Error: 281 2310 mpsse.c:174 open_matching_device(): libusb_get_device_list() failed with LIBUSB_ERROR_NO_DEVICE
JTAG drivers installed OK.
Any ideas please?
OpenOCD JTAG stopped working after Win10 uprade
Re: OpenOCD JTAG stopped working after Win10 uprade
Managed to fix this by ussing OpenOCD suppied with the new V4 tool chain v0.10.0-esp32-20190313 (2019-03-13-09:57) now it works again, but only if you use the WinUSB driver (not libWinUSB WinLIB) .
The error still comes up but the new version gets past this and makes the connection
The error still comes up but the new version gets past this and makes the connection