ESP32-S2-SOLO-U-N4: Boots only at second power-on

Davelec
Posts: 2
Joined: Thu Jan 05, 2023 9:33 am

ESP32-S2-SOLO-U-N4: Boots only at second power-on

Postby Davelec » Thu Jan 05, 2023 9:53 am

Hello ESP32 community,

I have designed a custom PCB with the ESP32-S2-SOLO-U-N4. Everything works fine except when I power-on the device after at least 2 minutes of OFF-time the ESP doesn't boot. When I power-off and power-on again everything is working fine.

At first I thought that the 3,3 V supply is rising to slow so that there is an issue with the reset. But looking at the oszilloscope everything looks the same at the first and at the second power-on. I have added the schematic and a screenshot from the oszilloscope.

Does anyone have an idea? For me it seams like there some Caps are loading too slow when they are completely empty at first power-on...
Attachments
ESP32-S2_Schematic.png
ESP32-S2_Schematic.png (111.83 KiB) Viewed 1157 times
photo_2023-01-05_10-27-22.jpg
Blue: 3,3V supply
Yellow: Reset
5ms/div
photo_2023-01-05_10-27-22.jpg (256.73 KiB) Viewed 1157 times

ESP_Sprite
Posts: 9589
Joined: Thu Nov 26, 2015 4:08 am

Re: ESP32-S2-SOLO-U-N4: Boots only at second power-on

Postby ESP_Sprite » Fri Jan 06, 2023 1:22 am

The 100n over the GPIO0 button likely makes the ESP32 go into download mode in the situations where it 'doesn't boot'. Remove that and the issue should go away.

Davelec
Posts: 2
Joined: Thu Jan 05, 2023 9:33 am

Re: ESP32-S2-SOLO-U-N4: Boots only at second power-on

Postby Davelec » Sun Jan 08, 2023 8:13 am

Thank you very much. That fixed the problem. Too easy :lol:

Who is online

Users browsing this forum: No registered users and 109 guests