I checked in my multimeter and in all cables it hovers between 4.6V and 4.7Vcostaud wrote:I think you can connect a oscilloscope to check the voltage of the 5V pin.
When RF circuit is working, it might take more current.
Search found 4 matches
- Wed Sep 26, 2018 8:50 am
- Forum: General Discussion
- Topic: Dust sensor throwing different values on change of usb cable
- Replies: 6
- Views: 7270
Re: Dust sensor throwing different values on change of usb cable
- Wed Sep 26, 2018 8:49 am
- Forum: General Discussion
- Topic: Dust sensor throwing different values on change of usb cable
- Replies: 6
- Views: 7270
Re: Dust sensor throwing different values on change of usb cable
The fact that you have brownouts indicates that you have a power supply setup that has voltage sag when some current is drawn, possibly because of thin USB cables. This may also affect the output of your dust sensor. Can you try to see if supplying external voltage to the board, e.g. by using a lab...
- Wed Sep 26, 2018 7:11 am
- Forum: General Discussion
- Topic: Dust sensor throwing different values on change of usb cable
- Replies: 6
- Views: 7270
Re: Dust sensor throwing different values on change of usb cable
I tried without wifi and BLE on but the same issue. Brownout issue is another issue I am facing but not that frequent but when that happens device goes to a reboot loop.
- Wed Sep 26, 2018 6:20 am
- Forum: General Discussion
- Topic: Dust sensor throwing different values on change of usb cable
- Replies: 6
- Views: 7270
Dust sensor throwing different values on change of usb cable
Hello, I have a dust sensor from Honeywell [https://sensing.honeywell.com/honeywell-sensing-hpm-series-particle-sensors-datasheet-32322550-e-en.pdf][ and which is connected to Vin(5v) of esp32 dev board. The problem I am facing is sensor throwing different values when I change USB cable which I use ...