Search found 1 match

by MartinStej
Mon Apr 08, 2019 7:26 pm
Forum: General Discussion
Topic: UART receive failure after 120 bytes
Replies: 4
Views: 7910

Re: UART receive failure after 120 bytes

Hi, same here. According to the technical reference (pg 336), default HW buffer size is simply 128 Bytes: UART_RAM.png I could verify that 128 Bytes is exactly edge where everything works. According to the technical reference it is possible to reorganize it. For example when you're not using TX, you...